Back to www.openers-closers.com
3EAZ45 Electronic Strike

3EAZ45

3EAZ45 Series 3 Electronic Strike 8-30V AC/DC 5,800N Internal Hold-open

Technical Data

FunctionInternal Hold-open
OperationFail-secure
Resistance to forced entry5,800 N
Endurance Rating (Cycles)200,000
Operating Temperature-25ºC − +70ºC
Sound Level AC (at 50 cm)69 dBA
Sound Level DC (at 50 cm)5 dBA
Latch Spring Force17-18 N
Door Opening Direction (DIN 107)DIN R / DIN L
Vertical and Horizontal InstallationYes
Strike Fixing Distance52.5 mm
Height (Z)138 mm
Width (X)22.1 mm
Depth (Y)28 mm
KeeperAdjustable
Radian KeeperExternal
Keeper Movement34º
Keeper DepthR 15 mm
Keeper Adjustment3 mm

Product Certificates

Regulations(UE) 305/2011
StandardsEN 14846:2008
EMC Directive2014/30/UE
RoHS Directive2011/65/UE
REACH Regulation1907/2006

Connection

Connection 3EAZ45 Electronic Strike

Electrical Data (at 20°C)

CoilZ
Nominal Voltage8-30V AC/DC
Rated Resistance8 Ω
Duty Cycle (%ED)100% ED
Transient Voltage Suppressor (TVS)Yes
PCB Firmware Versionstd-z_V.1.1.0
PCB Hardware VersionPCBA0000101

Consumption Tables showing relation between Tension (Vin), Consumption (A) and Preload Force (N)

Alternating Current (AC)

Vin (AC)

Initial

C0(A)1C1(A)2DIN L (N)4DIN R (N)5

Holding

C2(A)3
6
80.90.391502000.24
9
10
121.020.446506500.24
14
16
22
240.820.356506500.13
28
301.280.56506500.13

Direct Current (DC)

Vin (DC)

Initial

C0(A)1C1(A)2DIN L (N)4DIN R (N)5

Holding

C2(A)3
6
80.760.353001500.19
9
10
120.980.416504500.17
14
16
22
241.10.196504500.08
28
301.340.196505000.08
1 C0: Peak current. 2 C1: Initial Consumption. 3 C2: Holding Consumption. 4,5 Preload Force in Newtons (N) DIN L, DIN R (With preload, the strike processes the opening in under 1 second).
The table shows the test values at a temperature of 20°C; any variation in this condition will affect both the power consumption and the holding force of the electric strike. Consumption deviation of ±7% due to ohmic tolerance of coil.