Back to www.openers-closers.com
3UBX00 Electric Strike

3UBX00

3UBX00 Series 3 Electric Strike 10-24V AC/DC 8,000N Internal Hold-open with mechanical unlocking

Technical Data

FunctionInternal Hold-open with mechanical unlocking
OperationFail-secure
Resistance to forced entry8,000 N
Endurance Rating (Cycles)200,000
Operating Temperature-25ºC − +70ºC
Sound Level AC (at 50 cm)69 dBA
Sound Level DC (at 50 cm)5 dBA
Latch Spring Force17-18 N
Door Opening Direction (DIN 107)DIN R / DIN L
Vertical and Horizontal InstallationYes
Strike Fixing Distance52.5 mm
Height (Z)71 mm
Width (X)20.1 mm
Depth (Y)32 mm
KeeperFixed
Radian KeeperExternal
Keeper Movement34º
Keeper Depth9 mm
Keeper Adjustment0 mm

Product Certificates

Regulations(UE) 305/2011
StandardsEN 14846:2008
EMC Directive2014/30/UE
RoHS Directive2011/65/UE
REACH Regulation1907/2006

Connection

Connection 3UBX00 Electric Strike

Electrical Data (at 20°C)

CoilX
Nominal Voltage10-24V AC/DC
Rated Resistance42 Ω
Duty Cycle (%ED)100%ED(10-12V AC/DC) / <1min (>12V AC/DC)
Transient Voltage Suppressor (TVS)Yes
PCB Hardware VersionPCBA0000001

Consumption Tables showing relation between Tension (Vin), Consumption (A) and Preload Force (N)

Alternating Current (AC)

Vin (AC)

Initial

C0(A)1C1(A)2DIN L (N)4DIN R (N)5

Holding

C2(A)3
6
8
9
100.180.181201500.18
120.210.212002000.21
14
16
22
240.460.462002500.46
28
30

Direct Current (DC)

Vin (DC)

Initial

C0(A)1C1(A)2DIN L (N)4DIN R (N)5

Holding

C2(A)3
6
8
9
100.220.2210100.22
120.260.2610300.26
14
16
22
240.510.51701200.51
28
30
1 C0: Peak current. 2 C1: Initial Consumption. 3 C2: Holding Consumption. 4,5 Preload Force in Newtons (N) DIN L, DIN R (With preload, the strike processes the opening in under 1 second).
The table shows the test values at a temperature of 20°C; any variation in this condition will affect both the power consumption and the holding force of the electric strike. Consumption deviation of ±7% due to ohmic tolerance of coil.