OC890
OC890 Series OC Electropiston Lock glass mounted 12V DC Fail-safe
Series OC 

Technical Data
| Function | Fail-safe |
| Installation Type | Glass |
| Timer Delay | 0s/3s/6s/9s |
| Door Status | Yes |
| Bolt Status | Yes |
| Measurements | Block | Counterplate |
| Height (Z) | 150 mm | 150 mm |
| Width (X) | 32 mm | 30 mm |
| Depth (Y) | 43 mm | 24.4 mm |
Electrical Data (at 20°C)
| Nominal Voltage | 12V DC |
| Duty Cycle (%ED) | ED 100 % |
| Rated Operational Voltage Tolerance | ± 10 % |
| Power | 1.8 W |
Connection
Consumption Relation between Tension (Vin) and Consumption (A)
Direct Current (DC)
| Vin (DC) |
|
| |||||||
|---|---|---|---|---|---|---|---|---|---|
| 12 |
| 0.15 | |||||||
| 24 |
| — | |||||||
1 C0: Peak current. 2 C1: Initial Consumption. 3 C2: Holding Consumption.