3SCE30 Series 3 Electric Strike 12V DC 8,000N Timed fail-secure with hold-open

Technical Data

FunctionTimed fail-secure with hold-open
OperationFail-secure
Resistance to forced entry8,000 N
Endurance Rating (Cycles)200,000
Operating Temperature-25ºC − +70ºC
Sound Level AC (at 50 cm)69 dBA
Sound Level DC (at 50 cm)5 dBA
Latch Spring Force17-18 N
Door Opening Direction (DIN 107)DIN R / DIN L
Vertical and Horizontal InstallationYes
Strike Fixing Distance52.5 mm
Height (Z)77.7 mm
Width (X)20.1 mm
Depth (Y)28 mm
KeeperFixed
Radian KeeperExternal
Keeper Movement34º
Keeper Depth9 mm
Keeper Adjustment0 mm

Product Certificates

Regulations(UE) 305/2011
StandardsEN 14846:2008
EMC Directive2014/30/UE
RoHS Directive2011/65/UE
REACH Regulation1907/2006

Connection

Connection

Timer

Pulse TimeNominal TimingTiming Error
0.5s7s± 3s
1s12s± 4s
2s17s± 5s
3s20s± 5s

Electrical Data (at 20°C)

CoilE
Nominal Voltage12V DC
Rated Resistance42 Ω
Duty Cycle (%ED)100% ED
Transient Voltage Suppressor (TVS)Yes
PCB Firmware VersionNA
PCB Hardware VersionV.1.3

Consumption Tables showing relation between Tension (Vin), Consumption (A) and Preload Force (N)

Alternating Current (AC)

Vin (AC)

Initial

C0(A)1C1(A)2DIN L (N)4DIN R (N)5

Holding

C2(A)3
6
8
9
10
12
14
16
22
24
28
30

Direct Current (DC)

Vin (DC)

Initial

C0(A)1C1(A)2DIN L (N)4DIN R (N)5

Holding

C2(A)3
6
8
9
10
120.260.2610300.26
14
16
22
24
28
30
1 C0: Peak current. 2 C1: Initial Consumption. 3 C2: Holding Consumption. 4,5 Preload Force in Newtons (N) DIN L, DIN R (With preload, the strike processes the opening in under 1 second).